KISVI JEWELRY leading manufacturer and exporter of fashionable jewelry in China.
Sales & Support 86-86--15814532055
Request A Quote
Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Sitemap
HomeProductsParallel Redundant UPS

RS232 IGBT inverter three phase Parallel Redundant UPS, 10KVA, 220 / 380VAC

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

RS232 IGBT inverter three phase Parallel Redundant UPS, 10KVA, 220 / 380VAC

Large Image :RS232 IGBT inverter three phase Parallel Redundant UPS, 10KVA, 220 / 380VAC

Product Details:

Detailed Product Description

RS232 IGBT inverter three phase Parallel Redundant UPS, 10KVA, 220 / 380VAC
 

1. Can be parallel max 8pcs  charger
2. N+X Modular ups system
3. Internal audio alarm system
 
DSP series 10K-200KVA:

1. Pure sine wave output,  true on-line dual conversion design

2. Adopt 4 layer PCB,  and SMD technology.

3. The sixth generation IGBT,  the inverter has high efficiency,  low temperature,  high reliability.

4. Touch screen display,  with the simple operation and Intuitive data,  optional display language and logo.

5. Set the work mode on the display directly,  UPS mode,  ECO mode,  EPS mode.

Intelligent detecting function

6. Excellent load feature, it is completely capable to load from 0-100% while no need to change to bypass
7. Three phase separately control,  realizes the control of instantaneous over-loading balance,  so as to reach 100% unbalanced load.

8. Cold start

9. Generator compatible

10. RS232 and RS485 standard collocation,  optional SNMP and dry contact

11. Perfect protection.

12. Selectable battery inspection module

13. High-powered dynamic feature

14. Optional input harmonic filter 

15.http://www.baykeepower.cn,  http://en.baykee.net

 

Model

DSP10K

DSP20K

DSP30K

DSP40K

DSP60K

DSP80K

DSP100K

DSP200K

Nominal capacity KVA

10KVA

20KVA

30KVA

40KVA

60KVA

80KVA

100KVA

200KVA

Work mode

parallel max 8pcs the same model

Phase 

3phase+N+G

Input power factor

>0.9   or >0.95(optiom)

Rectifier

Nominal input 

voltage

220/380VAC ;230/400VAC ; 240/415VAC

Range

+/-25%

Nominal 

input frequency

50Hz+/-10%  ;  60Hz+/-10%

Output ripple

Less than 2%

Soft start

0-100%  5sec

Charge

Charge mode

constant current to constant voltage,  with temp compensation; with Auto change

Float Voltage

432VDC

Boost Voltage

445VDC

Temperature 

compensation 

voltage

3mV/ 1 pcs

Charge current

0.1C( automatically change follow the batteries )

Charge frequency

20% of  Rated capacity

Battery

Battery Type

maintenance-free lead acid battery

Battery capacity

7--999AH settable (according to the capacity)

Battery number

32pcs 12V or  192pcs 2V(Nominal voltage 384VDC)

Inverter  

Phase

Three phase+N

Capacity

Rated capacity *0.8

Nominal  voltage

220/380VAC  ; 230/400VAC  ;  240/415VAC

Output voltage 

stability

+/-1%( Stable  load); +/-3%( fluctuant load)

Output frequency 

stability

50Hz/60Hz<+/-0. 5%

Creast factor

> 3:1

Output waveform 

distortion

Sine wave , linear load<3%;non-linear load<5%

Dynamic 

characteristics

 Instant voltage<+/-5%(from 0 to100% ),  

Instant recover time<10mS

Unbalanced 

load voltage

<+/-5%

Overload Protection

105% 10 m;125%1S;150% 10 ms

efficiency

>95%(full load)

Bypass

Phase

Three phase +N

Nominal  voltage

220/380VAC ;230/400VAC ; 240/415VAC

Transfer time

<1mS( static switch with 0 transfer time )

Protection

Input protection

Input voltage/frequency over limited ;wrong phase; lack  phase

Output protection

Over current  short circuit ; factor low protection

Battery protection

Over charge ; over-discharge protection

Temperature

 protection

Ambient  over temperature protection;

 inverter over temperature protection

Hardware  failure  

protection

Assistant power abnormal,  breaker cut off , breaker overload, power components  over current/over voltage etc protection

System 

Parameters

Working 

environment

Temp: 0~40,  relative humidity 30%~90 %;(a 1% decrease against 100 meters’ rise. Altitude 4000m MAX)

cooling -down

 method

COMPULSIVE VENTILATION(with temperature control)

Communication 

Interface

RS232, RS485; optional SNMP card (for internet long distance monitor )

Redundancy 

function

In series or N+1 parallel

Anti-surge 

capacity

10/700μS, 5KV ;8/20μS, 20KA

Protection level

IP21 or IP31

 Safety 

Performance

Vin-n  Vout-n 3000Vac,  creepage<3.5mA  isolation resistance >3M(500VDC)

Product Tag :
Contact details

Send your inquiry direct to us. (0 / 3000)

RS232 IGBT inverter three phase Parallel Redundant UPS, 10KVA, 220 / 380VAC related products
Three phase four wires
Modular Parallel Redundant
DSP Series Parallel